BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CACEA | Canadian Association of Consulting Energy Advisors - ECPv6.15.17.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://staging.cacea.ca
X-WR-CALDESC:Events for CACEA | Canadian Association of Consulting Energy Advisors
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Toronto
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20250309T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20251102T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20270314T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20271107T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Toronto:20260115T120000
DTEND;TZID=America/Toronto:20260115T180000
DTSTAMP:20260424T221757
CREATED:20251031T205014Z
LAST-MODIFIED:20251215T185025Z
UID:8534-1768478400-1768500000@staging.cacea.ca
SUMMARY:Residential Duct Air Flow Measurement: Assessing the impact of air flow on ASHP sizing
DESCRIPTION:Duct capacity is often a limiting factor in sizing retrofit heat pumps\, and contractors often size heat pumps based on the existing air conditioner\, resulting in under-sized equipment. A simple 15-minute test can provide definitive air flow capacity of a duct system\, contributing to a proper sized heat pump and avoiding poor system performance—such as noise problems due to restrictive ductwork. Energy Advisors (EA) can easily add this procedure to the scope of an Energy Evaluation. \nThis training will instruct EAs on how to evaluate the airflow capacity of duct systems in homes where the distribution system is not being changed and the primary retrofit measure is the replacement of heating and cooling equipment. In conjunction with other considerations—such as the CSA F280-12 Heat Loss/Heat Gain value—this is a preliminary assessment to provide the homeowner and their HVAC Contractor with data that will help the contractor select the largest ASHP based on existing ductwork. Please note: This course does not enable EAs and other HOT2000 modelers to select specific heat pumps or make direct sizing recommendations. The Contractor is ultimately responsible for equipment selection. \nInstructor and CACEA member Mark Rosen MEA\, Director\, Building Science\, Building Knowledge Canada and a well-known professional architect\, trainer\, and consultant who is passionate about buildings that perform exceptionally well.
URL:https://staging.cacea.ca/event/residential-duct-air-flow-measurement-assessing-the-impact-of-air-flow-on-ashp-sizing/
LOCATION:Virtual via Zoom\, Canada
CATEGORIES:Training,Webinar
END:VEVENT
END:VCALENDAR